
Periodicidad semestral: flujo continuo.
ISSN - Electrónico: 2661-6947 / DOI: 10.36015 • LILACS BIREME (19784); LATINDEX (20666)
Introduction: we intend to compare the complications related to the subclavian/axilar puncture versus cephalic vein cut down in pacemaker implantation. Materials and methods: all procedures between january 2010 and december 2013 were included. We excluded pulse generator substitution, unsuccessful implantations, jugular or femoral access and implantation performed outside the electrophysiology laboratory. We analyzed early complications such as pocket hematoma, pocket infection, pneumothorax, lead displacement, re intervention and death. Results: 161 procedures were analyzed. Pocket infection presented in 3,7% with subcalvian/axilar access and in 1,25% with cephalic access (p:0,27). Pocket hematoma presented in 2,49% with subclavian/axilar access vs 1,25% with cephalic access (0,57). There were atrial lead displacement in 2,5% with cephalic access vs 1,23% with subcalvian/axilar access (p:0,56). Ventricular lead displacement presented in1,23% with subclavian/axilar access vs 1,25% with cephalic access (p:0,99). Pneumothorax presented in 2,49% with subclavian/axilar access vs 0% with cephalic access (p:0,29). We reported one death with cephalic access (p: 0,49). Re intervention was needed in 6,1% with subclavian/axilar access vs 3,75% with cephalic access (p:0.48). Conclusion: complication rates presented no differences between subclavian/axilar access and cephalic access.
Kim Rajappan. Permanent pacemaker implantation technique: part I. Heart 2009;95;259-264
Kim Rajappan. Permanent pacemaker implantation technique: part II. Heart 2009;95;334-342
Garay Juan Ignacio. Modificación de Técnica Seldinger: cómo introducir dos catéteres a través de un mismo acceso utilizando una punción venosa central única. Flebología y linfología – Lecturas vasculares / a;o 6 No 16 / septiembre-diciembre 2011
Capellino Pablo, Benavidez Flavio, Perriello Juan, Ramos Raúl, Pierini Leandro. Cateterización venosa subclavia. Revista del Hospital Privado de Comunidad 2003;vol 6, no 2
Asensio Enrique, Mont Lluís,. Rubín José M, Herreros Benito, Ninot Salvador y cols. Estudio prospectivo, comparativo entre implantes de marcapasos realizados en el laboratorio de electrofisiología y en el quirófano. Rev Esp Cardiol 2000; 53: 805-809
Seymour Furman. Venous Cutdown for Pacemaker Implantation.
Ann Thorac Surg 1986;41:438-439
Kolettis Theofilos, Lysitsas Dimitrios, Apostolidis Dimitrios, Baltogiannis Giannis Eleni, Sourla, y cols. Improved ‘cut- down’ technique for transvenous pacemaker lead implantation. Europace (2010) 12, 1282–1285
Kossaify Antoine, Nicolas Nayla and Edde Pierre. Hemoptysis After subclavian Vein puncture for pacemaker Implantation: Importance of Wire-Guided Venous puncture. Clinical Medicine Insights: Case Reports 2012:5
Darlington E, Rittoo D, Patel B, Choi K. Pacemaker implantation using real-time ultrasound guidance for subclavian nein access. Heart may 2012 Vol 98 Suppl 1
Schiariti Michele, Cacciola Mariateresa and Puddu Paolo.
Complications of Pacemaker Implantation, Modern Pacemakers - Present and Future, Prof. Mithilesh R Das (Ed.),2011. ISBN: 978-953-307-214- 2
McGee David and Gould Michael. Preventing Complications of Central Venous Catheterization. N Engl J Med 2003;348:1123-33
J. C. J. Res, JA de Priester, AAK van Lier, C.L.J.M van Engelen, P.NA Bronzwaer, P-H.Tan, M. Visser. Pneumothorax resulting from subclavian puncture: a complication of permanent pacemaker lead implantation. Neth Heart J 2004;12:101-5.
Femenía Francisco, Arce Mauricio, Peñafort Fernando, Arrieta Martín, Gutiérrez Daniel. Complicaciones del implante de marcapaso definitivo. ¿Un evento operador dependiente? Análisis de 743 pacientes consecutivos. Arch Cardiol Mex 2010;80(2):95-99
Sohail Muhammad, Uslan Daniel, Khan Akbar, Friedman Paul, Hayes David y cols. Infective Endocarditis Complicating Permanent Pacemaker and Implantable Cardioverter-Defibrillator Infection. Mayo Clin Proc. 2008;83(1):46-53
Wiegand UK, LeJeune D, Boguschewski F, Bonnemeier H, Eberhardt F, Pocket hematoma after pacemaker or implantable cardioverter defibrillator surgery: influence of patient morbidity, operation strategy, and perioperative antiplatelet/anticoagulation therapy. Chest. 2004 oct;126(4):1177-86
Julio de Oliveira, Martino Martinelli, Silvana D’Orio, Tania Varejao, David Uipe y cols. Efficacy of Antibiotic Prophylaxis Before the Implantation of Pacemakers and Cardioverter- Defibrillators. Circ Arrhythmia Electrophysiol. 2009;2:29-34
Fuertes Beatriz, Toquero Jorge, Arroyo-Espliguero Ramón, Lozano Ignacio. Pacemaker Lead Displacement: Mechanisms And Management. Indian Pacing Electrophysiol. J. 2003;3(4):231-238
Syamkumar Divakara, Glen Sumner, Carlos Ribas, Jeff. Healey, Girish Nair y cols. Contralateral Pneumothorax in Left Sided CRT Device Implantation. Indian Pacing and Electrophysiology Journal (ISSN 0972-6292), 11 (1): 16-19 (2010)
Res J, Priester J, Van Lier L, Van Engelen C y cols. Pneumothorax resulting from subclavian puncture: a complication of permanent pacemaker lead implantation. Neth Heart J. 2004 march; 12(3): 101–105.
Nicola Schulza, Klaus Pu Schelb, Elisabeth E. Turkc. Fatal complications of pacemaker and implantable cardioverter- defibrillator implantation: medical malpractice? Interactive CardioVascular and Thoracic Surgery 8 (2009) 444–448
The authors who publish in this journal accept the following conditions:
1. The authors retain the copyright and grant to the CAMbios MEDICAL-SCIENTIFIC JOURNAL HECAM the right of the first publication, with the work registered with the Creative Commons attribution license, which allows third parties to use the published material provided that they mention the authorship of the work and the first publication in this journal.
2. Authors can make other independent and additional contractual agreements for the non-exclusive distribution of the version of the article published in this journal (for example, include it in an institutional repository or publish it in a book) as long as it clearly indicates that the work was published. for the first time in the CAMbios MEDICAL-SCIENTIFIC JOURNAL HECAM.